European Heat-Resistant Cable: FZ-LSi/FZ-LS/Neon Light Cables

European Heat-Resistant Cable: FZ-LSi/FZ-LS/Neon Light Cables

uropean Part-No.Description, Conductor Color & Cross-sec. mm2Cond. make-up
n x wire ØOuter
Diameter
mmCopper Weight
kg/kmWeight
ca. kg/kmAWG23110
FZ-LSi Ignition Cable 16 kV, blue, 0.57 x 0.35.04.836.02023106FZ-LSi Ignition Cable 16 kV, blue, 1.019 x 0.257.59.565.01723107FZ-LSi Ignition Cable 16 kV, blue, 1.528 x 0.268.514.488.016 European Part-No.Description, Conductor Color & Cross-sec. mm2Cond. make-up
n x wire ØOuter
Diameter
mmCopper Weight
kg/kmWeight
ca. kg/kmAWG23109
FZ-LS High Voltage Ignition Cable 15/20 kV, red-brown, 1.019 x 0.255.09.634.01723108FZ-LS High Voltage Ignition Cable 15/20 kV, red-brown, 1.019 x 0.257.09.660.017 European Part-No.Description, Conductor Color & Cross-sec. mm2Cond. make-up
n x wire ØOuter
Diameter
mmCopper Weight
kg/kmWeight
ca. kg/kmAWG23147
Neon Light Cable 3.5kV, 4.5kV & 7.5kV, yellow, 1.530 x 0.254.414.432.01623148Neon Light Cable 3.5kV, 4.5kV & 7.5kV, yellow, 1.530 x 0.256.614.459.01623149Neon Light Cable 3.5kV, 4.5kV & 7.5kV, yellow, 1.530 x 0.257.614.475.016

Technical DataEuropeanFZ-LSi, blue

  • Test Voltage 20 kV
  • Breakdown Voltage min. 30 kV
  • Ignition Voltage (kV eff.)
    0.5 mm² = 6 kV
    1.0 mm² = 8 kV
    1.5 mm² = 10 kV

FZ-LS, red

  • Test voltage
    for 5 mm Ø = 15 kV
    for 7 mm Ø = 20 kV
  • Breakdown voltage
    for 5 mm Ø: min. 25 kV
    for 7 mm Ø: min. 35 kV

Neon-light-Cable, yellow

  • Nominal voltage
    3.5 kV, 4.0 kV / 7.5 kV
  • Test voltage 10 kV
  • Specific volume resistive
    min. 1012 Ohm x cm
  • Minimum bending radius
    approx. 7.5x cable Ø
  • Radiation resistance
    up to 20x106 cJ/kg (up to 20 Mrad)
  • Tinned copper stranded conductor, strand make-up see table below
  • Silicone conductor insulation 2GI1 to DIN VDE 0207 part 20
  • Glass-fiber braiding
  • Outer-jacket silicone 2GM1 to DIN VDE 0207 part 21
  • Jacket color: Blue

FZ-LS, red

  • Adapted to ISO 3808 part 1
  • Tinned copper conductor, 19x0.25 mm Ø
  • Silicone conductor insulation 2GI1 to DIN VDE 0207 part 20
  • Jacket color: Red Brown

Neon-light-cable, yellow

  • in adapted to DIN VDE 0250 part 1 and part 5
  • Tinned copper stranded conductor 30x0.25 mm Ø
  • Silicon conductor insulation 2GI1 to DIN VDE 0207 part 20
  • Jacket color: Yellow

Application FZ-LSi, blue
This ignition cable is suitable for use at high and extremely alternating temperatures up to +180°C/+356°F and also for motor vehicle sector. As protection against mechanical damages a glass fiber braiding and a silicone jacket covers the conductor insulation.
FZ-LS, red
This ignition cable is suitable for use at high and extremely alternating temperatures up to +180°C/+356°F. Applications include the lamp and lighting industry and cooling and air conditioning technology.
Neon-light-cable, yellow
This cable is primarily suitable for use at high and extremely alternating ambient temperatures such as in the lamp and lighting industry. Protected installation is required.

  • Halogen-free according to VDE 0482 part 267 / DIN EN 50267-2-2/ IEC 60754-2 (equivalent DIN VDE 0472 part 813)
  • No flame propagation according to DIN VDE 0482 part 265-2-1 / EN 50265-2-1 / IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)
  • No formation of corrosive gases
  • Low smoke density
  • Very good weather resistance

ارتباط باسازمان

این بخش کلیه راههای ارتباطی و وبسایتهای مرتبط باپردیس کابل را نمایان میکند همچنین تمام نقطه تماسهای شبکه های اجتماعی متصل به ساختمان پردیس کابل دراین بخش نمایش داده میشوند.

suport mail:[email protected]